Battery Input Data |
Battery Type |
Lead–acid or Lithium–ion |
Battery Voltage Range (V) |
51.2V/48V |
Max. Charging Current (A) |
110A |
Max. Discharging Current (A) |
110A |
Charging Curve |
3 Stages / Equalization |
External Temperature Sensor |
Yes |
Charging Strategy for Li–lon Battery |
Self-adaption to BMS |
PV STRING INPUT DATA |
Max. DC Input Power(W) |
8000W |
PV lnput Voltage (V) |
100-480Vdc |
MPPT Range (V) |
100-385Vdc |
Full Load DC Voltage Range |
100-480Vdc |
Start–up Voltage (V) |
120V |
PV lnput Current (A) |
13A + 13A |
Max. PV Input Voltage (V) |
500 |
No. of Strings Per MPPT Tracker |
1/1 |
AC OUTPUT DATA |
Rated AC Output and UPS Power(W) |
5000 |
Max. AC Output Power(W) |
5000 |
Peak Power (off grid) |
2 times of rated power, 10S |
AC Output Rated Current(A) |
23 |
Max. AC Current(A) |
25 |
Max. Continuous AC Passthrough(A) |
35A |
Power Factor |
0.8 leading to 0.8 lagging |
Output Frequency and Volfage |
50/60Hz; 220/230Vac (single phase) |
Grid Type |
Single Phase |
Current Harmonic Distortion |
THD<3%(Linear load<1.5%) |
EFFICIENCY |
Max. Efficiency |
97.60% |
Euro Efficiency |
96.50% |
MPPT Efficiency |
99.90% |
PROTECTION |
PV Input Lightning Protection |
Integrated |
Anti-island Protection |
Integrated |
PV String Input Reverse Polarity Protection |
Integrated |
Insulation Resistor Detection |
Integrated |
Residual Current Monitoring Unit |
Integrated |
Output Over Current Protection |
Integrated |
Output Shorted Protection |
Integrated |
Output Over Voltage Protection |
Integrated |
Surge Protection |
DC Type ll / AC Type ll |
CERTIFICATION AND STANDARDS |
Grid Regulation |
UL1741SB, IEEE1547: 2018, HECO SRD 2.0 |
|
SafetyRegulation |
IEC62109-1/-2 |
EMC |
|
GENERAL DATA |
Operating Temperature Range(°C) |
|
Cooling |
Smart Cooling |
Noise(db) |
<30 db |
Communication with BMS |
RS485; CAN |
Weight (kg) |
14kg |
Size (mm) |
330Wx433Hx238D |
Protection Degree |
IP65 |
Installation Style |
Well-mounted |
Warranty |
2 Years |
Reviews
There are no reviews yet.