Cellcronic Galaxy 4.4KW Version 10G Pro Plus-24V Heavy Duty Hybrid Inverter
Cellcronic Galaxy 4.4KW Version 10G Pro Plus-24V Heavy Duty Hybrid Inverter
Key Specifications & Features
-
AC Coupling: Retrofit existing solar systems.
-
Dual Mode: On-grid & Off-grid operation.
-
24V DC Design: Compatible with Lead-Acid & Lithium (LiFePO4) batteries.
-
MPPT Voltage Range: 150V–425V DC.
-
Smart Monitoring: Intelligent IoT-based Wi-Fi connectivity.
-
Dual Output: Separate normal & heavy load outputs.
-
Lightweight Design: Only 10 kg.
-
Dimensions: 380 × 380 × 120 mm.
-
Design Life: 20–25 years.
Model Galaxy 4.4K Version 10G Pro Plus Hybrid Inverter Battery Input Data Battery Type Lead–acid or Lithium–ion Battery Voltage Range (V) 20~30V Max. Charging Current (A) 171A Max. Discharging Current (A) 171A Number of Battery Input 1 Charging Strategy for Li–lon Battery Self-adaption to BMS PV STRING INPUT DATA Max. PV Input Power(W) 7200W Max. PV Input Voltage (V) 500V Start–up Voltage (V) 125V MPPT Voltage Range (V) 370 (150-425V) MPPT Input Range(V) 150-425 Max PV Input Current (A) 15A Max. Short-Circuit Current (A) 18A No.of MPP Trackers 1 No. of Strings Per MPPT Tracker 1 AC INPUT/OUTPUT DATA Rated AC Input/Output Active Power (W) 4400 Max. AC Input/Output Apparent Power (VA) 5500 Rated AC Input/Output Current (A) 19.1 Max AC Input/Output Current (A) 23.9 Max. Continuous AC Passthrough(A) 29A Peak Power (off grid) (w) 2 times of rated power, 10S Power Factor Adjustment Range > 0.99 @rated power (Adjustable 0.8 LD – 0.8 LG) Rate Input/Output Voltage(V) 220/230 Rated Input/Output Grid Frequency/Range(Hz) 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz Grid Connection Form L+N+PE (Single Phase) Total Current Harmonic Distortion THDi THD<3%(Linear load <1.5%) DC Injection Current <0.5% In EFFICIENCY Max. Efficiency (PV to AC) 97.60% Eur. Efficiency (PV to AC) 96.50% MPPT Efficiency 99.90% PROTECTION AC Output Overcurrent Protection Integrated AC Output Overvoltage Protection Integrated AC Output Short Protection Integrated Thermal Protection Integrated DC Terminal Insulation Impedance Monitoring Integrated Ground Fault Current Monitoring Integrated Island Protection Monitoring Integrated DC Input Switch Integrated Residual Current Detection (RCD) Integrated Surge Protection TYPE II(DC),TYPE II(AC) INTERFACE Display LCD+LED Communication Interface RS485,CAN Monitor Mode WIFI GENERAL DATA Operating Temperature Range(°C) -40-60°C(>45°C derating) Permissible Ambient Humidity 0-100% Permissible Altitude 2000m Noise <55dB Parallel Not Supported Cooling Air Cooling Ingress Protection(IP) Rating IP65 Inverter Topology Non-Isolated Weight (kg) 10Kg Size (W*H*D) (mm) 380*380*120(Excluding connectors and brackets) Over Voltage Category OVC II(DC),OVC III(AC) Installation Style Well-mounted Warranty 5 Years/ Expendable up to 10 years EMC/Safety Regulation IEC/ED 62109-1 IEC/EN 62109-2,IEC/EN 61000-6-1, IEC/EN 61000-6-3
Key Features & Specifications
IP65 protection degree.
Pure sine wave output.
Compatible with solar panels and wind turbines.
5500W maximum load & 7200W solar capacity.
Programmable battery charging/discharging.
Maximum charging/discharging current.
5-year warranty, extendable up to 10 years.
Also works with generators.