| Model |
Galaxy 7G PRO 18kw-48v Three Phase DUAL MPPT Hybrid Inverter |
| Battery Input Data |
| Battery Type |
Lead–acid or Lithium–ion |
| Battery Voltage Range (V) |
40~60V |
| Max. Charging Current (A) |
350A |
| Max. Discharging Current (A) |
350A |
| Charging Curve |
3 Stages / Equalization |
| Number of Battery Input |
1 |
| Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
| PV STRING INPUT DATA |
| Max. DC Input Power(W) |
30000W |
| Max. PV input Voltage (V) |
800V |
| MPPT Voltage Range (V) |
160V-650V |
| Start-up Voltage (V) |
160V |
| Rated PV Input Voltage (V) |
550V |
| Max. Operating PV Input Current (A) |
36+20 |
| Max. Input Short-Circuit Current (A) |
54+30 |
| No. of MPPT Trackers |
2 |
| No. of Strings Per MPPT Tracker |
2+1 |
| AC OUTPUT DATA |
| Rated AC Input/Output Active Power (W) |
20000W |
| Max. AC Input/Output Apparent Power (VA) |
22000W |
| Peak Power (off-grid) |
2 times of rated power, 10S |
| Rated AC Input/Output Current (A) |
30.4/29 |
| Max. AC Input/Output Current (A) |
30.4/29 |
| Max. Continuous AC Passthrough (grid to load) (A) |
70A |
| Output Frequency and Voltage |
50/45-55Hz; 220/380V, 230/400V 0.85Un-1.1Un |
| Grid Connection Form |
3L+N+PE (Three Phase) |
| Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
| Current Harmonic Distortion |
<3% (of nominal power) |
| DC Injection Current |
<0.5% In |
| EFFICIENCY |
| Max. Efficiency |
97.60% |
| Euro Efficiency |
97.00% |
| MPPT Efficiency |
99.90% |
| PROTECTION |
| DC Polarity Reverse Connection Protection |
Integrated(Except European Type) |
| AC Output Overcurrent Protection |
Integrated |
| AC Output Overvoltage Protection |
Integrated |
| AC Output Short Circuit Protection |
Integrated |
| Thermal Protection |
Integrated |
| DC Terminal Insulation Impedance Monitoring |
Integrated |
| DC Component Monitoring |
Integrated |
| Ground Fault Current Monitoring Power Network Monitoring |
Integrated |
| Island Protection Monitoring |
Integrated |
| Earth Fault Detection |
Integrated |
| DC Input Switch Overvoltage Load Drop Protection |
Integrated |
| Residual Current (RCD) Detection |
Integrated |
| Surge protection level |
Integrated |
| Surge Protection |
TYPE II(DC), TYPE II(AC) |
| CERTIFICATION AND STANDARDS |
| Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
| Safety Regulation |
IEC/EN 61000-6-1/2/3/4 |
| EMC |
IEC/EN 62109-1, IEC/EN 62109-2 |
| GENERAL DATA |
| Operating Temperature Range(°C) |
-40 to +60℃, >45℃ Derating |
| Cooling |
Intelligent Air Cooling |
| Noise(dB) |
≤60 dB |
| Inverter Topology |
Non-Isolated |
| Permissible Ambient Humidity |
0-100% |
| Permissible Altitude |
3000m |
| Over Voltage Category |
OVC II(DC), OVC III(AC) |
| Communication with BMS |
RS485; CAN |
| Weight (kg) |
50.6 Kg |
| Size (mm) |
456×750×268.5 (Excluding Connectors and Brackets) |
| Protection Degree |
IP65 |
| Installation Style |
Well-mounted |
| Warranty |
6 Years/10 Years |